MXD33 60KVA Feature:
The 60 KVA UPS online pure sine wave battery backup uninterruptible power supply (UPS) and power conditioner with surge protection automatically provides defense against power problems. Give your electronics longer life while protecting them from harmful dirty power problems that may otherwise damage or degrade their performance.

60kva ups three phase


1.Built-in Output Isolation Transformer

2.It adopts industrial grade powerful high-speed centrifugal fan for heat dissipation, intelligent speed regulation and low noise

3.The output waveform has high quality and good load characteristics

4.IGBT uses space vector modulation technology to greatly improve DC voltage utilization and reduce the harmonic content, the same capacity battery backup time is longer.

5.The human-machine interface adopts a liquid crystal touch screen


ups pure sine wave 60kva

60kva ups for medical60kva ups three phaseups pure sine wave 60kva


Model

60K

Input

Main input supply

Rated voltage

380VAC (Line voltage) /220VAC (Phase voltage)

Input wiring

3Ф + N + E(Protective earth)

Voltage range

(165±5~275±5)VAC (Phase voltage)

Low voltage lose/recovery

(165±5) VAC / (180±5) VAC (Phase voltage)

High voltage lose/recovery

(275±5) VAC/ (260±5) VAC (Phase voltage)

Bypass

Rated voltage

380/220VAC

Input wiring

3Ф + N + E (Protective earth)

Voltage range

(165±5~275±5) VAC (Phase voltage)

Low voltage lose/recovery

(165±5) VAC / (180±5) VAC (Phase voltage)

High voltage lose/recovery

(275±5) VAC/ (260±5)VAC (Phase voltage)

Input frequency

Rated frequency

50Hz/60Hz

Low frequency lost

46Hz/56Hz

Low frequency recovery

46+0.5Hz/56+0.5Hz

High frequency lost

54Hz/64Hz

High frequency recovery

54-0.5Hz/64-0.5Hz

Input performance

Input power factor

0.75 (220VLinear full load )

Generator input

Support (Generator rated power  2 UPS rated power)

Input current

Rated current

135A

Output

Output power

Rated VA/Watt

60KVA/ 48KW

Rated voltage

380VAC(Line voltage)/220VAC (Phase voltage)

Output voltage range

200/208/220/230/240VAC (Output power reduces to 90% 208/200V)

Voltage regulation

±2 %

THD V

Full RCD load

Linear full load

Phase regulation

120±1°

Voltage transient response

≤9% (Linear load 0%~100%~0%)

Transient response recovery time

≤60mS (Nonlinear load) recovery to 90%

Bypass before turn on

Yes

Model

60K

Crest ratio

3 : 1

Output frequency range

Line mode

46Hz~54Hz /56Hz~64Hz(The same as input frequency)

50Hz/60Hz (Line frequency>(54Hz /64Hz) or line frequency<(46Hz/56Hz)

Battery mode

(50+0.1) Hz/(60+0.1) Hz

Slew rate

1 Hz/Sec

Efficiency

Line mode

> 90%

Battery mode

> 93%

Overload function

Line mode/ Battery mode

Overload warning only; 105%±5%≤load

2Min, then transfer to bypass and alarm; 105%±5%<load≤125%±5%

30S, then transfer to bypass and alarm; 125%±5%<load≤150%±5%

0.5S, then transfer to bypass and alarm; load>150%±5%

Automatically recovery

Yes

Short protection

Line mode/ Battery mode

Cut off output after 3s

Transfer time

Line mode to Battery mode

0mS

Battery mode to line mode

0mS

Line mode to Bypass mode

<1mS

Bypass mode to line mode

<1mS

Battery and Charger

Battery

Rated voltage

384VDC

Protection

Low battery alarm/recovery

(361.6V±4V)/ (377.6V±4V)

Battery shutdown voltage

(320V±4V)/ (336V±4V)

Battery protection

Battery overcharge protection

(475V±4V)

Battery detect

Battery missing

Support

Battery failure

Support

Charge

Float charge voltage

(440±2)VDC

Charge time

Depending on the battery capacity

Charge current

10A ( Adjustable )

Interface

Alarm mute

Support

DC boot

Support

Auto Reboot

Support

Alarm function

Battery mode

Beep once every 4 second

Low battery voltage / Charger fault

Beep once every second

Model

60K

UPS fault

Beep continuously

Overload

Beep once every second

Bypass

Beep once every 2 minute

Communication interface

RS232/ RS485

Support

Output dry contact

Support

Intelligent slot

Support SNMP/AS400

Supervisory software

Support

Cooling way

Forced air cooling

Show

LCD+LED

Environment

Working temperature

0℃~40℃

Altitude

<1000m

Noise

70dB

Storage temperature

-15℃~45℃

Work humidity

20% ~ 95%

Standard

EMS/EMI

Anti-interference

IEC 61000-4-2.4.5 Level IV, IEC61000-4-3 Level III

Conduction

IEC62040-02

Radiation


Safety

Safety

GB4943-2001/IEC62040-1

Mechanical properties

Connection

Input

Terminal blocks

Output

Terminal blocks

Battery interface

Terminal blocks

Other function

60Hz

Support

Frequency mode

Support

ECO

Support(option)

EPO

Support


60kva ups for medical60kva ups three phaseups pure sine wave 60kva60kva ups for medical